6 X 2MW Electric Power Station Four Stroke Generator Set Pressure Lubrication Method
Technical specificaiton for HFO Power plant equipments | |||
Ⅰ. Gen-set technical specification | |||
No. | Item | Unit | Specification |
1 | Model | 1250/2000/2500/3500GF | |
2 | Rated power | kW | 1250/2000/250003500 |
3 | Rated rev. | rpm | 600 |
4 | Rated voltage | V | 11000 |
5 | Rated current | A | 229.6 |
6 | Frequency | Hz | 50Hz |
7 | Power factor | 0.8 (lagging) | |
8 | Phase | 3-phase | |
9 | Voltage fluctuation rate | % | ±1 |
10 | Frequency (rev.) fluctuation rate | % | ±0.5 |
11 | Stable voltage regulating rate | % | ±2.5 |
12 | Stable frequency (rev.) regulating rate | % | 5 |
13 | Transient voltage regulating rate | % | ±20~-15 |
14 | Stabilizing time | s | 5 |
15 | Voltage regulating method | Auto | |
16 | Speed Governor | Electronic hydraulic | |
17 | Frequency regulating method | Auto/Manual | |
18 | Lubricating method | Pressure lubricating | |
19 | Cooling method | Close circuit of fresh cooling water | |
20 | Coupling | Flexiable | |
21 | Painting color | Blue | |
22 | Overall dimension | mm | 9890x2560x4015 |
23 | Net weight | kg | 75000 |
Ⅱ. Diesel engine specification | |||
No. | Item | Unit | Specification |
1 | Engine Model | DN8340ZD2 | |
2 | Type | In-line, 8-Cyls, four-stroke, direct injection, charged, inter cooled | |
3 | Bore | mm | 340 |
4 | Stroke | mm | 450 |
5 | Total displacemen | L | 408.35 |
6 | Mean piston seed | m/s | 9 |
7 | Rated power | KW | 4200 |
8 | Rated rev. | rpm | 600 |
9 | Overload (1 hr per 12 hrs) | kW/rpm | 4620/600 |
10 | Mean effective pressure | MPa | 2.56 |
11 | Compression ratio | 13.5 | |
12 | Rotation direction | Clockwise, viewed from flywheel end. | |
13 | Firing order | 1-4-7-6-8-5-2-3 | |
14 | Specific fuel oil consumption | g/kW.h | 198+3% |
15 | Specific Lube oil consumption | g/kW.h | < 1.2g/kW.h |
16 | Smoke | RB | ≤0.3 |
17 | Noise | dB(A) | 105 |
18 | Starting method | Air Rotary valve | |
19 | Cooling system | Fresh water cooling | |
20 | Lubricating system | Pressure lubricating | |
21 | Fuel oil specification | Diesel oil and 720Cst/50℃ HFO | |
22 | Lube oil specification | CD40 with TBN according HFO | |
23 | Piston lifting height | mm | 2365 |
24 | Overall dimension | mm | 7213×1850×3625mm |
25 | Net weight | kg | 47000 |
Ⅲ. Alternator specification | |||
No. | Item | Unit | Specification |
1 | Alternator Model | TFW3800 | |
2 | Type | Brushless generator | |
3 | Rated power | kW | 3500 |
4 | Rated voltage | V | 11000 |
5 | Rated current | A | 229.6 |
6 | Frequency | Hz | 50 |
7 | Power factor | 0.8 (lagging) | |
8 | Working condition | Continuous | |
9 | Phase and connection | 3-phase | |
10 | Voltage regulation method | Brushless, self excited | |
11 | Insulation Class | F | |
12 | Protection Class | IP23 | |
Ⅳ Cooling tower specification | |||
No. | Item | Unit | Specification |
1 | Cooling tower model | GBL-150 | |
2 | Inlet temperature | ℃ | 60 |
3 | Outlet | ℃ | 35 |
4 | Base Plane Size | mm | Ф4460×5095 |
5 | Blade amount | 4 | |
6 | Fan diameter | mm | Ф3400 |
7 | Motor fan power | kW | 11 |
8 | Inlet pipe demension | mm | DN200 |
9 | Outlet pipe demension | mm | DN250 |
The power fuel can be diesel oil, bio-diesel, heavy fuel oil (HFO) or bi-fuel
G300 Statinary Generating Sets Main Specification | ||||||||
Model | 1000GF1 | 1250GF3 | 1350GF4 | 1400GF4 | ||||
Rated power, KW | 1000 | 1250 | 1350 | 1400 | ||||
Overload , KW | 1100 | 1375 | 1485 | 1540 | ||||
Rated voltage, V | 400/415/440/3300/6300/10500/13800 | |||||||
Rated current , A | ||||||||
Frequency , Hz | 50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
Power factor | 0.8 Lagging | |||||||
Phase | 3 | |||||||
Diesel engine | G6300ZD6 | G6300ZD8 | G8300ZD6 | G6300ZD10 | G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 |
Rated power, KW | 1103 | 1470 | 1471 | 1471 | 1765 | 2000 | 1765 | 2000 |
Rated rev, rpm | 500 | 600 | 500 | 600 | 500 | 600 | 500 | 600 |
Alternator | 3 phase alternator | |||||||
voltage fluctuation rate% | <0.5 | <0.5 | ||||||
Frequency fluctuation rate, % | <0.5 | <0.5 | ||||||
Stable voltage regulating rate, % | ±1.0 | ±1.0 | ||||||
Transient voltage regulating rate, % | +20, -15 | +20, -15 | ||||||
Stable Frequency fluctuation rate, % | <3 | <0.5 | ||||||
Transient frequency regulating rate, % | +12, -10 | |||||||
Stablizing time, voltage , S | <4 | |||||||
Stablizing time, frequency , S | <3 | |||||||
voltage regulating method | automatic and munual | |||||||
Frequency regulating method | manual | |||||||
starting method | compressed air | |||||||
Lubricating method | pressue lubricating | |||||||
Cooking method | water cooling | |||||||
coupling | flexible | |||||||
Overdimension, mm | 3880*2150*3180 | 8470*2360*3060 | ||||||
Weight, Kg | 30000 | 35000 | 38000 |
G300 Statinary Generating Sets Main Specification | |||||||
1500GF6 | 1600GF5 | 1800GF7 | 2000GF8 | ||||
1500 | 1600 | 1800 | 2000 | ||||
1650 | 1760 | 1980 | 2200 | ||||
400/415/440/3300/6300/10500/13800 | |||||||
50 | 60 | 50 | 60 | 50 | 60 | 50 | 60 |
0.8 Lagging | |||||||
3 | |||||||
G8300ZD10 | G8300ZD8 | G8300ZD10 | G8300ZD8 | G8300ZD8 | G8300ZD8 | G8300ZD12 | G8300ZD8 |
1765 | 2000 | 1765 | 2000 | 2000 | 2000 | 2206 | 2000 |
500 | 600 | 500 | 600 | 600 | 600 | 600 | 600 |
3 phase alternator | |||||||
<0.5 | |||||||
<0.5 | |||||||
±1.0 | |||||||
20, -15 | |||||||
<0.5 | |||||||
+20, -15 | |||||||
<5 | |||||||
<4 | |||||||
automatic and munual | |||||||
manual | |||||||
compressed air | |||||||
pressue lubricating | |||||||
water cooling | |||||||
flexible | |||||||
8470*2360*3060 | |||||||
38000 | 42560 |
Remark
1. the generator voltage and frequency can be selected
2. rating for the generator set is based on the following standard conditions
air temperature :25℃
total barometric pressure 100kpa
charge air coolant temperature 25℃
relative humidity 30%
If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000
3. The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position
GN8320 Stationary Generating Sets Main Specification | ||||||||||
Model | 2400GF | 2500GF | ||||||||
Rated power, KW | 2400 | 2500 | ||||||||
Overload , KW | 2640 | 2750 | ||||||||
Rated voltage, V | 400 | 415 | 3300 | 6300 | 10500 | 400 | 415 | 3300 | 6300 | 10500 |
Rated current , A | 4330 | 4174 | 525 | 275 | 165 | 4511 | 4348 | 547 | 172 | 286 |
Frequency , Hz | 50 | 50 | ||||||||
Power factor | 0.8 Lagging | 0.8 Lagging | ||||||||
Phase | 3 | 3 | ||||||||
Diesel engine | GN832000ZD | GN8320ZD | ||||||||
Rated power, KW | 2648 | 2795 | ||||||||
Rated rev, rpm | 750 | 750 | ||||||||
Alternator | 3 phase alternator | |||||||||
voltage fluctuation rate% | ±1.0 | |||||||||
Frequency fluctuation rate, % | +12, -10 | |||||||||
Stable voltage regulating rate, % | 3 | |||||||||
Transient voltage regulating rate, % | +12, -10 | |||||||||
Stable Frequency fluctuation rate, % | 4 | |||||||||
Transient frequency regulating rate, % | 5 | |||||||||
Stabilizing time, voltage , S | +1 | |||||||||
Stabilizing time, frequency , S | +12, -10 | |||||||||
voltage regulating method | automatic and manual | |||||||||
Frequency regulating method | manual | |||||||||
starting method | compressed air | |||||||||
Lubricating method | pressure lubricating | |||||||||
Cooking method | water cooling | |||||||||
coupling | flexible | |||||||||
Overdimension, mm | 8950*2570*6050 | |||||||||
Weight, Kg | 45000 |
Remark
1. the generator voltage and frequency can be selected
2. rating for the generator set is based on the following standard conditions
air temperature :25℃
total barometric pressure
charge air coolant temperature
relative humidity
If test ambient conditions are not same as the standard ambient conditions, the power and fuel consumptions should be revised according to GB/T6072.1-2000
3. The generator set can operate under overload, intermittently for 1 hour every 12h, the fuel injection quantity is usualy locked in the rated power position
KANGWEI ENVIRONMENT ENERGY GROUP
KANGWEI ENVIRONMENT ENERGY UNITED GROUP
KWEE has engaged in design and production for more than 20 years, With the many years accumulated mature development, the business range had included the large power diesel engine generator set and relevant auxiliary fuel oil system equipment as well as the environment protection
KWEE cover the land area of 187500m2, with building area of 155000m2. Annual sales turnover is more than 60 million Yuan RMB. There are more than 450 employees, 50 of which have high-grade professional title, and 120 have middle-grade professional title. There are more than 2,000 large-sized production of engine equipment and auxiliries. The company is capable of manufacturing more than 5,000 engine generator set, more than 2,000 separators or purifiers ,additionally more than 1,000 non-standard equipment used in the marine and power plant each year.
It has over 50 proprietary technologies,Our company had passed the
international quality system identification, such as ISO14001and
ISO9001. All equipments which designed and manufactured by us apply
to the system of diesel generator set and land based HFO fired
power plant, also specialized for the manufacturing diesel engine
generator set , combined fuel oil and LO system treatment module,
fuel oil booster unit, combined LO/cooling water module which
controlled by manual and PLC automatic, centrifugal oil purifier
unit, boiler system; most of the products build up the good
reputation in the market and have recognized by the international
classification society at home and abroad, such as CCS,BV,ABS,ASME
etc, KWEE had become a one-stop integrated solutions provider for the marine power
system and HFO power plant.
KWEE also mainly focuses on the development of environment protection businesses especially the environment energy and water, developed the integrated ability for the environment technology designing, development, currently have the enough specialized ability to finish the environment project construction and engineering, such as biomass power generation
KWEE will positively continue to promote the healthy and good development for the system of diesel engine genset and environment protection, expect to build up good business cooperation with you in the future with our higher quality services.
* THE JOINT STOCK GROUP COMPANY LIST
QINGDAO BOYANG DIESEL ENGINE CO.,LTD
----- DIESEL ENGINE DESIGN AND MANUFACTURING
WUXI KANGWEI ENVIRONMENT ENERGY EQUIPMENT CO.,LTD
----- LARGE GENERATOR AUXILIARY SYSTEM AND ENVIRONMENT PROTECT SYSTEM
WUXI WEILIT BOILER CO.,LTD
----- BOILER MANUFACTURING FACTORY
WUXI JINGGAN SEPARATOR EQUIPMENT CO.LTD
----- CENTRIFUGAL SEPARATOR AND PURIFIER MANUFACTURING FACTORY