All-in-One design, Integrated IEC61850 SV & GOOSE, 6I+7V analog channels output, Inbuilt GPS and IRIG-B, and other advance functions.
Complied IEC61850-9-1, IEC61850-9-2, IEC60044-7/8, etc
100/1000Mbit Fiber port for SMV and GOOSE simulations
6x35A & 7x310V independent high burden output channels
13 channels independent low-level signal outputs
AC/DC measurement (8 channels inputs, 0.1 class, 0-600V/0-5A, auto range)
Transducer calibration (0.02 class)
Energy meter calibration (Mechanical & Electronic meters)
Transient play back up to 3KHz
Lightweight, <18Kg
Fully function KRT software testing modules
3-Years guarantee of free repair and life-long maintenance
Free software upgrade
Model | Current Outputs | Voltage Outputs |
K3166 | 6×35A @ 450VA max / 3×70A @ 850VA max | 7×130V @ 75VA max |
K3166i | 6×35A @ 450VA max / 3×70A @ 850VA max | 7×310V @ 90VA max |
K3163 | 6×35A @ 450VA max / 3×70A @ 850VA max | 4×130V @ 75VA max |
K3163i | 6×35A @ 450VA max / 3×70A @ 850VA max | 4×310V @ 124VA max |
K3130 | 3×35A @ 450VA max | 4×130V @ 75VA max |
K3130i | 3×35A @ 450VA max | 4×310V @ 124VA max |
Able of what K31 series can test
Items | ANSI® No. |
IEC61850 numerical IEDs relay & merge unit | |
Distance protection relay | 21 |
Synchronising or synchronism-check relays | 25 |
Undervoltage relays | 27 |
Directional Power relays | 32 |
Undercurrent or underpower relays | 37 |
Negative sequence overcurrent relays | 46 |
Overcurrent/ground fault relays | 50 |
Inverse time overcurrent/ground fault relays | 51 |
Power factor relays | 55 |
Overvoltage relays | 59 |
Voltage or current balance relays | 60 |
Directional overcurrent relays | 67 |
Directional ground fault relays | 67N |
DC overcurrent relays | 76 |
Phase-angle measuring or out-of-step protection relays | 78 |
Automatic reclosing devices | 79 |
Frequency relays | 81 |
Motor overload protection relays | 86 |
Differential protection relays | 87 |
Directional voltage relays | 91 |
Voltage and power directional relays | 92 |
Tripping relays | 94 |
Voltage regulating relays | |
Overimpedance relays, Z> | |
Underimpedance relays, Z | |
Time-delay relays |
Characteristics
Variable battery simulator, DC 0-350V, 140Watts max.
13 Low-level channels outputs up to 8Vac/10Vdc max.
0-600V / 0-5A AC/DC measurement in 0.1 class.
Graphical test modules and templates for testing of various relays
Quick relay testing facility in Manual mode
Shot/Search/Check, Point & Click testing
RIO/XRIO import & export facility
Switch on to fault test(SOTF)
Power system model for dynamic testing
Inbuilt GPS and IRIG-B sync end-to-end testing
Online Vector display
Automatic test results assume
Automatic test report creation
Anti-clipping detect, Wrong wiring connect alarm and self-protect, overload and overheat protection
Parameter
Voltage Outputs | ||||
Output Range & Power | 7×310 V ac (L-N) | 90 VA max each | ||
3×620 V ac (L-L) | 180 VA max each | |||
3×350 V dc (L-N) | 140 W max each | |||
Accuracy | AC: <0.03%Rd+0.01Rg Typ. <0.07%Rd+0.03Rg Guar. | |||
DC: ±10mV @ <5V, ±0.5% @ ≥5V | ||||
Resolution | 1mV | |||
Distortion | <0.05%Typ. / <0.1% Guar. | |||
Current Outputs | ||||
Output Range & Power | 6×35A ac (L-N) | 450 VA max each | ||
3×70A ac (2L-N) | 850 VA max each | |||
1×100A ac (6L-N) | 1200 VA max | |||
3×20A dc (L-N) | 300W max each | |||
Accuracy | AC: <0.05%Rd+0.02Rg Typ. <0.15%Rd+0.05Rg Guar. | |||
DC: ±5mA @ <1A, ±0.5% @ ≥1A | ||||
Resolution | 1mA | |||
Distortion | <0.05%Typ. / <0.1% Guar. | |||
13 Low-Level Channel Outputs | ||||
Quantity | 13 Channels, 16 pin aviation socket | |||
Voltage Outputs Range | AC 0~8V, DC 0~10V | |||
Current Outputs Range | Nominal 2mA, 10mA max transient | |||
Output Power | ≥0.5VA | |||
Accuracy | (0.01~0.8 Vrms):<0.05% Typ. / <0.1% Guar. (0.8~8 Vrms): <0.02% Typ. / <0.05% Guar. | |||
Resolution | 0.25mV | |||
Distortion(THD%) | <0.05% Typ. / <0.1% Guar. | |||
Frequency & Phase Angle | ||||
Frequency Range | DC~1KHz, 3KHz transient | |||
Frequency Accuracy | ±1ppm | |||
Frequency Resolution | 0.001 Hz | |||
Phase Range | -360°~360° | |||
Phase Accuracy | <0.05° Typ. / <0.1° Guar. 50/60Hz | |||
Phase Resolution | 0.001° | |||
IEC61850 Fiber & GOOSE Ethernet Ports (Optional Function) | ||||
Fiber Ports | 2 x 100Base-FX Full Duplex, LC type (Optional to 10/100Mbit, Ethernet RJ45 type) | |||
Fiber Type | 62.5/125um (Multiple optical fiber, Orange Red) | |||
Wavelength | 1310nm | |||
Transmit Distance | >1Km | |||
Indicator | Spd Green(light): Valid connection Link/Act Yellow(Blinking): Data exchanging | |||
Note: | All hardware of this module are ready for active | |||
Aux. DC Voltage Source (Battery simulator) | ||||
Range | 0~350V @ 140W max | |||
Accuracy | 0.5%Rg Guar. | |||
Binary Input | ||||
Quantity | 8pairs | |||
Type | wet/dry, measurement | |||
Threshold | 10~600Vdc or potential free, Programmable | |||
Time resolution | 100us | |||
Debounce time | 0~25ms (Software Controlled) | |||
Time range | Infinite | |||
Time errors | ±1ms @ 0.001~1s, ±0.1% @ >1s | |||
Galvanic isolation | 4 isolated with each 2 pairs | |||
Binary Output (Relay Type) | ||||
Quantity | 4pairs | |||
Type | Potential free relay contacts, software controlled | |||
Break Capacity AC | Vmax: 400Vac / Imax:8A / Pmax:2500VA | |||
Break Capacity DC | Vmax: 300Vdc / Imax:5A / Pmax:150W | |||
Binary Output (Semiconductor Type) | ||||
Quantity | 4pairs | |||
Type: | Open-collector, 14 pin Aviation socket | |||
Break Capacity DC | 5~15Vdc / 5mA, 10mA max AC not permit | |||
Response time: | 100us | |||
Synchronization | ||||
Synchronization Mode | GPS, SMA type antenna connector IRIG-B, FT3 IEEE1588 | |||
Power supply & Environment | ||||
Nominal Input Voltage | 100~240Vac | |||
Permissible Input Voltage | 85~264Vac, 125~350VDC | |||
Nominal Frequency | 50/60Hz | |||
Permissible Frequency | 45Hz~65Hz | |||
Power Consumption | 1500 VA max | |||
Connection Type | Standard AC socket 60320 | |||
Operating Temperature | -10℃~55℃ | |||
Storage Temperature | -20℃~70℃ | |||
Humidity | <95%RH, non-condensing | |||
Others | ||||
PC Connection | RJ45 Ethernet, 10/100/1000M | |||
Grounding Terminal | 4mm banana socket | |||
Weight | 18 Kg | |||
Dimensions(W x D x H) | 468×375×164(mm) |
Additional Information (Optional Modules)
DC Measurement Input (Transducer calibrator) | |||
Voltage Input | Range | 0~±10V dc | |
Max Input | ±11V dc | ||
Accuracy | <0.02% rg Typ. <0.05% rg Guar. | ||
Input Impedance | 1Mohm | ||
Current Input | Range | 0~±1mA / 1~±20mA, auto range | |
Max Input | 600mA | ||
Accuracy | <0.02% rg Typ. <0.05% rg Guar. | ||
Input Impedance | 15 ohm | ||
AC/DC Measurement Input (Standard meter) | |||
Input Quantity | 8 inputs (blend with binary input pairs) | ||
Voltage range | 0~600Vrms (Rg:0.1V,1V, 10V, 60V, 600V) | ||
Voltage accuracy | <0.1% Rg | ||
Current range | 0~5Arms(clamp input) | ||
Current accuracy | <0.1% Rg | ||
Sample rate | 10KHz | ||
Input impedance | 600KΩ | ||
Frequency range | 45~65Hz, Accuracy < 0.01Hz | ||
Phase accuracy | 0~360°, <0.2° Typ. | ||
Transient Recorder | |||
Input Quantity | 8 input channels (blend with binary input pairs) | ||
Recorder time | Max 50 Sec. | ||
Energy Meter Calibration | |||
Sensor Usage | Mechanical meters / Electronic meters | ||
Sensor Output | High lever:>4.5V, Low level:<0.2V | ||
Pulse Input | 1 pulse input port | ||
Pulse Range | 500KHz pulse input Max. | ||
Pulse Output | 1 Transistor output, Open-collector, 5-15Vdc/5mA |
Kingsine Electric Automation Co., Ltd.
Who am I ?
Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, and Instrumentation. To date, Kingsine's products have been recognized by customers in more than 80 countries worldwide. We regularly participate in large-scale power and energy exhibitions worldwide, including in the United States, Italy, France, Poland, Australia, Dubai, Turkey, Brazil, Philippines, Malaysia, Indonesia, South Africa, Egypt, and other countries, and have received widespread acclaim.Our protection relay testing equipment is compatible with world-renowned relay protection devices such as ABB, SIEMENS, ALSTOM, MITSUBISHI, Schneider, AREVA, SEL, GE, and others. Kingsine Electric has also established a distribution network with partners in the Americas, Europe, Asia, the Middle East, and other countries to provide comprehensive services.
Kingsine is a core supplier to China's State Grid
The facts demonstrate that China's annual power generation has remained the world's number one, with a projected power generation of 840 billion kilowatt hours in 2022, compared to the United States' projected 430 billion kilowatt hours in the same year. China has built the world's most advanced power transmission system for DC current at 1100KV ultra-high voltage levels and more than 11,000 digitized substations based on the IEC61850 standard. China's power grid has the largest, most advanced, safest and most stable power system in the world. We are honored to be the core supplier for State Grid Corporation of China.
Where did I come from?
Kingsine Electric is located in Shenzhen, the "Innovation Capital of China". We have also established subsidiaries in Canada and Hong Kong. Shenzhen is a benchmark city for the development of China's high-tech industry and is home to leading Chinese companies in various industries. Many of China's top companies, including Huawei, the world's largest communication company; DJI, the world's largest commercial drone company; BYD, the world's largest electric vehicle company (which sold 1.86 million electric vehicles globally in 2022, surpassing Tesla's sales of 1.37 million); and Tencent, one of China's leading internet companies, are based in Shenzhen. Excellent enterprises can influence each other, and as the world's factory, Shenzhen has a highly advanced and comprehensive industrial chain, which provides a reliable guarantee for Kingsine Electric to develop, produce, and manufacture high-tech, high-quality, and reliable products.
Where am I going?
Philosophy
Adhering to the belief of novelty in technology and detail in service, and gradually establishing a global service and sales network with worldwide partners and distributors, Kingsine shall spare no effort to serve customers worldwide with innovative technology, reliable products, and quality online service, making electric testing easier across the world.
Business Principles
Kingsine's business principle is to create value for customers, which is reflected in three aspects.
Firstly, Kingsine uses advanced technology to create powerful product features that offer customers a great operating experience.
Secondly, Kingsine provides high-quality products and services at reasonable prices, ensuring that customers receive high value for their investment.
Thirdly, Kingsine emphasizes reliability and after-sales service, providing quality assurance through lean production and ensuring that products have over 15 years of service life and three years of warranty. Kingsine's after-sales maintenance principle is based on cost accounting, ensuring that after-sales service remains efficient and affordable.Based on our modular product design philosophy, and with the help of efficient video diagnostics, our target for after-sales maintenance service is to complete repairs within 20 days.