Dental Low Speed Handpiece Kit Dental Handpiece Repair Kit, Dental External Kit
Features:
Contra angle handpiece
Low Speed 22,000-27,000 rpm
The shank of the instrument mounted therein is 2.35 mm
Fastening of the instruments with a turning latch
Autoclavable 135°C
For any lab or E-type motors
Color Style | Silver |
Chuck | Key Type |
Spray | External water spray |
Hole | 2 or 4 Holes |
Air Pressure | 0.3-0.35Mpa |
Rotation Speed | 14,000-22,000 rpm |
Noise | ≤65 dB |
Straight Handpiece
Working pressure: 0.3MPa
0.25MPa(Measure meter is installed at the end of air motor to
measure the air pressure)
Revolution: about 22000-27000r/min (adjustable between clockwise or
anticlockwise)
Noise: ≤70dB
Air consumption: about 56L/min
Ratio: 1:1
Max speed of contra angle: 25000rpm/min
Air Motor:
Supply air pressure: 245-392KPa (2.5-4kgf/CM2)
1:1 Direct Drive
Borden 2 holes/Midwest 4 holes
Max speed 20,000 min-1
Air-in Pressure(kg/cm2) | Motor Rotation(rpm) | Air Wastage:(N1/min) |
2.5 | 22,000 | 42 |
3 | 25,000 | 51 |
4 | 27,000 | 72 |
WAYS OF LOADING AND UNLOADING BURS:
(1). Straight handpiece: When unloading the bur, please turn the
stuck, until you hear a sound.
And loading the bur, you turn the stuck to the opposite side. When you hear a sound, the bur has been fixed
(2). Contra angle handpiece: Screw the clip and put the bottom of bur to the axle center, then turn the clip to the original place.
Unloading the bur, screw the clip and take the bur out.
CLEAN AND LUBRICATE:
(1). Air motor: Load the pipe from motor. For example drip some
lubrication into the air pipe at the bottom.
Lubricate it after every use, drip 2 drops.
(2). Straight handpiece: Turn the spray head to the mouth of
lubrication.When unloading the bur, put the spray head to the
handpiece and ensure that the head of handpiece show sigh of
oil.(at least 2 seconds). Don't invert oil tin when using
lubrication.
(3). Contra angle handpiece: Loose the winding part of SH, take the
conducting gear out. Lubricate the conducting part.Screw the clip
when lubircating the head of handpiece.
CAUTIONS:
Don't use damaged or winding burs. The damaged or winding burs will
cause accident if use.
Burs are hard to pull out if the gully part has damaged.
Please keep the clamping part clean, if it was stained, the
cartridge will shock or the strength of clamping part will weaken.
Please fix the burs, or the bearings will be damaged at early
stage. Don't use motor when the clip is loose or burs are not on.
Please install the burs or standard stick even not in usage.
Payment :
T/T, Western union, Paypal
Packing :
It includes Contra Angle Handpiece,Straight Handpiece With Air Motor
Shenzhen Rogin Medical Co., Ltd
Shenzhen Rogin Medical Co., Ltd is professional manufacturer and supplier of dental instruments, which is mainly engaged in research and development, production and sales of root canals files (such as rotary NiTi system, stainless steel/NITI files, barbed broaches, paste carriers, Gate Drills/Peeso Reamers, Gutta percha points and Absorbent paper points, Matrices, Burs and Polishing Discs, etc.), and we are also dealing with our cooperated factory in other dental products (such as orthodontic, handpieces, dental lab equipment and consumables, etc.) .
We are always doing our best to provide the best quality products
with competitive price to our customers, and we continue to improve
our quality controlling to ensure the quality and market
competitive ability year by year.
We hope to establish business relationship with dental distributors
and dentists from abroad and domestic in the basis of mutual
interest and benefit.